consider the following:
• The building footprint covers 95% of the small urban site.
• The first floor has an open floor plan that includes a lobby, bar, and restaurant.
• The plan can only accommodate one 500 sf mechanical room.
What mechanical system should the architect recommend?
Refer to the exhibit (urban commercial site sketch).

In the urban commercial site shown in the sketch, which is the most convenient location for a truck entrance and exit from the site?
An elementary school requires a renovation, selective demolition, and a major addition in order to accommodate a growing student population. An architectural firm has prepared schematic design plans incorporating the school's increased programmatic needs, including an enlarged library, cafeteria, and gymnasium; a secure courtyard; and additional space for administrative offices and classrooms. The main entrance was relocated in order to improve the traffic and pedestrian flow at the beginning and end of the school day, and additional parking was provided to comply with current zoning requirements. The existing single-story masonry building was built in 1950. Two small additions were built later: the north addition will be kept and repurposed, but the south addition will be demolished. The building contains asbestos and lead in roof soffits, floor tiles, pipe insulation, and window paint. All existing mechanical systems need to be replaced; new systems have not been selected. Considerations for the renovation include: The relocated front entrance must be easily recognizable, highly visible, and secure.Interior and exterior materials need to be durable and maintainable in order to withstand frequent
student abuse, but also economical due to strict budget limitations.Good indoor air quality and increased energy efficiency are priorities for the selection of mechanical
equipment.
After completion, the entire school should look uniform, without a distinctive difference between the existing
building and new addition.
Building information:
Construction Type is II-B.
The following resources are available for your reference:
Existing Plans, including site and floor plans
Proposed Plans, including site and floor plans
Cost Analysis
Zoning Ordinance Excerpts, for off-street parking requirements
IBC Excerpts, showing relevant code sections
ADA Standards Excerpts, showing relevant sections from the ADA Standards for Accessible Design
Which of the following types of heating system would be appropriate when the design requires a very compact system that has a low initial cost, is easily zoned, and has a quick response to temperature changes?
Which of the following strategies is most appropriate for a new shopping center to be constructed on a nearly flat site flowing into a municipal subsurface storm-drainage system that is at capacity during a 5-year storm?